UHV Electrode
UHV Electrode Specification
- Number of Specimens
- Single Electrode
- Max Height
- Varies as per design
- Hardness
- High (Material dependent, e.g., Tungsten, Molybdenum)
- Mounting Type
- Flange Mount
- Application
- Used in ultra-high vacuum systems, physical vapor deposition, electron microscopy, ion sources, spectrometry
- Specimen Size
- Customizable
- Interface Type
- Vacuum flange compatible
- Humidity
- < 10% RH (for optimal operation)
- Temperature
- Up to 250C
- Response Time
- Immediate upon activation
- Operating Voltage
- Typically up to 5 kV (customizable)
- Frequency
- DC/Low Frequency
- Equipment Type
- UHV Electrode
- Features
- Corrosion resistant, high thermal stability, low outgassing, precise fabrication
- Accuracy
- High Precision (stable electrical properties in UHV)
- Port Size
- Custom per requirement
- Gas Pressure
- UHV (Ultra High Vacuum)
- Automation Grade
- Manual
- Usage
- Laboratory/Research/Industrial UHV applications
- Machine Weight
- Approx. 2 kg
- Control Mode
- Manual
- Vacuum Compatibility
- UHV (down to 1010 mbar)
- Surface Finish
- Polished/Vacuum compatible
- Replacement Availability
- Custom on demand
- Electrode Material
- Tungsten, Molybdenum, Platinum (as per requirement)
- Leak Rate
- < 1x109 mbarL/s
- Service Life
- Long (Under UHV conditions)
- Connector Type
- Custom UHV Feedthrough
- Color
- Metallic (Natural Finish)
- Bakeout Temperature
- Up to 250C
- Insulation
- Ceramic (e.g., Alumina)
- Electrode Shape
- Rod, Plate, Wire (as per specification)
- Compliance Standard
- UHV standard, ISO/CF flanges
UHV Electrode Trade Information
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 1 Unit Per Week
- Delivery Time
- 1 Week
- Sample Available
- Yes
- Sample Policy
- Contact us for information regarding our sample policy
- Main Domestic Market
- South India
About UHV Electrode
Leading Edge UHV Electrodes: Unlocking Versatile Research and Application
Benefiting laboratories, research institutes, and industrial UHV setups, this UHV Electrode excels in physical vapor deposition, electron microscopy, ion sources, and spectrometry. Users rely on its superior accuracy and unmatched reliability. The electrodes high hardness, robust thermal stability, and flawless vacuum compatibility make it the tool of choice in demanding environments, thus distinguishing it as a favoured solution for advancing scientific and industrial applications.
Sample and Secure Purchase: Cost-Effective UHV Electrode Offerings
Take advantage of our exclusive offer: sample UHV Electrode units are available for evaluation. Each specimen is expertly packaged to ensure safety and integrity. After acceptance, delivery time is typically prompt and efficient. Obtain a tailored quotation that balances performance with optimal expenditure, streamlining your procurement process and enabling you to deploy top-tier equipment without delay.
FAQs of UHV Electrode:
Q: How do I select the appropriate electrode material for my application?
A: Material selection depends on your experimental or process requirements. Tungsten is ideal for high temperatures and durability; molybdenum offers similar properties with distinct conductivity, while platinum suits applications demanding chemical inertness. Our specialists can guide you to the best option.Q: What is the process for obtaining a custom UHV Electrode?
A: Contact us with your specifications, including electrode shape, port size, and preferred material. Our team will prepare a quotation and guide you through customization, from design to production, ensuring the end product matches your precise requirements.Q: When will my UHV Electrode order be delivered?
A: Delivery typically occurs within the timeframe stated in your customized quotation upon order confirmation. For items in stock, dispatch is immediate. Custom fabrications may require additional time, which will be specified during the quotation process.Q: Where are the UHV Electrodes primarily used?
A: These electrodes are utilized in laboratory, research, and industrial UHV systems, particularly in physical vapor deposition, spectrometry, ion sources, and electron microscopy, where stable and precise electrical properties are crucial.Q: What are the key benefits of using this UHV Electrode?
A: The UHV Electrode offers high accuracy, superior corrosion resistance, thermal stability, low outgassing, and a long service life under demanding vacuum conditionsdelivering reliable performance and reduced downtime.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Vacuum Measuring Instruments Category
Substrate Heater
Price 10000 INR / Unit
Minimum Order Quantity : 1 Unit
Humidity : 095% RH (noncondensing)
Power Supply : 220V AC, 50 Hz
Application : Thin film deposition, semiconductor processing
Digital Thickness Monitor
Price 40000 INR / Unit
Minimum Order Quantity : 1 Unit
Humidity : 20% 85% RH (noncondensing)
Power Supply : 220V AC, 50/60 Hz
Application : For precise thickness measurement of sheets, foils, textiles, films and papers
Digital Penning Gauge
Price Range 9000.00 - 17000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Humidity : 0 to 95% RH (noncondensing)
Power Supply : 230V AC, 50 Hz
Application : Vacuum measurement in scientific, industrial, and laboratory environments
Digital Pirani Gauge
Price Range 8000.00 - 15000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Humidity : 095% RH (noncondensing)
Power Supply : 230V AC, 50 Hz
Application : Measuring vacuum in laboratory and industrial processes
![]() |
THULIR VACUUM TECHNOLOGIES
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |